Fujian Guangda Fire Fighting Equipment Co., Ltd.
PRODUCT OVERVIEW
The traditional above-ground fire hydrants used in our country in the past were installed on both sides of the road or around ware-houses.When the part of the body exposed above the ground is accidentally hit (for example,a driver accidentally hits the fire hydrant),fire-fighting water will spray out in large quantities and accumulate in rivers,causing flooding,interrupting traffic,and even causing losses to nearby shops.
1. This anti-collision product has been researched by our company for many years, and the structure has been continuously opti-mized.The test results are good.When damaged by accidental collision,the fire-fighting water will not overflow,saving water resources and avoiding unnecessary economic losses;
2.After this product is accidentally broken, you only need to replace the broken part (safety bolt) before it can be put into use,and the maintenance cost is extremely low (unless the situation is particularly serious).
PRODUCT OVERVIEW
1. It must be designed and installed according to the National Construction Commission's "Atlas of Water Supply and Drainage Standards". During actual installation,the flange bend of the fire hydrant should be connected to the underground pipe as needed,or the flange bend should be removed and directly installed on the pipeline tee.
2.The installation height should be such that the red paint of the fire hydrant is partially exposed to the ground. It should be placed in a prominent location without affecting traffic.The main outlet should face the road.
3.Before installation,the mud and debris in the bend of the fire hydrant must be removed completely.
4.When using,use a special wrench to open the water outlet cover, connect the water hose or suction pipe, and then use the special wrench to open the valve disc to supply water.After use, the valve disc should be closed and the water outlet cover should be closed.
PRODUCT PARAMETERS
| Product model | Nominal pressure (Mpa) | water inlet | outlet | |||
|---|---|---|---|---|---|---|
| type | quantity | Caliber (mm) | type | Caliber(mm)×Quantity | ||
| SSF100/65-1.6 | 1.6 | flanged | 1 | 100 | inward-curving External thread type | KWS65×2 DN100×1 |
| SSF150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSF150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SST100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SST150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SST150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SSFT100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SSFT150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSFT150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SSW100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SSW150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSW150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SSFW100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SSFW150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSFW150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SSP100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SSP150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSP150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SSPF100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SSPF150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSPF150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||
| SSPFT100/65-1.6 | 1.6 | 1 | 100 | KWS65×2 DN100×1 | ||
| SSPFT150/65-1.6 | 1.6 | 1 | 150 | KWS65×2 DN150×1 | ||
| SSPFT150/80-1.6 | 1.6 | 1 | 150 | KWS80×2 DN150×1 | ||