Anti collision pressure regulating ground fire hydrant SSFT100/65-1.6
+
  • Anti collision pressure regulating ground fire hydrant SSFT100/65-1.6

PRODUCT OVERVIEW
The SSFT series anti-collision and pressure-regulated outdoor fire hydrants are based on ordinary fire hydrants with key parts im-proved to make them more practical. The structure adopts a spring-closed drain port and achieves positive pressure sealing. Make it have:
1.Switch quickly.It only takes 4~5 turns of the wrench to completely close and open.
2.Voltage regulating function. Due to the pressure of the fire water, the internal pressure reducing device is opened in sections. First,a part of the water flows upward through the pressure reducing device, and then the other section is opened after being opened for a pe-riod of time,thus achieving the decompression effect.
3. Anti-collision function. If this fire hydrant is broken, the valve can automatically close and stop the water immediately. It does not affect the normal use of other fire hydrants in the same pipeline.It can repair damaged accessories under pressure. It is the first choice product for municipal projects.

 

PRODUCT OVERVIEW 
1. It must be designed and installed according to the National Construction Commission's "Atlas of Water Supply and Drainage Standards". During actual installation,the flange bend of the fire hydrant should be connected to the underground pipe as needed,or the flange bend should be removed and directly installed on the pipeline tee. 
2.The installation height should be such that the red paint of the fire hydrant is partially exposed to the ground. It should be placed in a prominent location without affecting traffic.The main outlet should face the road. 
3.Before installation,the mud and debris in the bend of the fire hydrant must be removed completely. 
4.When using,use a special wrench to open the water outlet cover, connect the water hose or suction pipe, and then use the special wrench to open the valve disc to supply water.After use, the valve disc should be closed and the water outlet cover should be closed.

 

PRODUCT PARAMETERS

Product modelNominal pressure (Mpa)water inletoutlet
  typequantityCaliber (mm)typeCaliber(mm)×Quantity
SSF100/65-1.61.6flanged1100inward-curving
External thread type
KWS65×2  DN100×1
SSF150/65-1.61.61150KWS65×2  DN150×1
SSF150/80-1.61.61150KWS80×2  DN150×1
SST100/65-1.61.61100KWS65×2  DN100×1
SST150/65-1.61.61150KWS65×2  DN150×1
SST150/80-1.61.61150KWS80×2  DN150×1
SSFT100/65-1.61.61100KWS65×2  DN100×1
SSFT150/65-1.61.61150KWS65×2  DN150×1
SSFT150/80-1.61.61150KWS80×2  DN150×1
SSW100/65-1.61.61100KWS65×2  DN100×1
SSW150/65-1.61.61150KWS65×2  DN150×1
SSW150/80-1.61.61150KWS80×2  DN150×1
SSFW100/65-1.61.61100KWS65×2  DN100×1
SSFW150/65-1.61.61150KWS65×2  DN150×1
SSFW150/80-1.61.61150KWS80×2  DN150×1
SSP100/65-1.61.61100KWS65×2  DN100×1
SSP150/65-1.61.61150KWS65×2  DN150×1
SSP150/80-1.61.61150KWS80×2  DN150×1
SSPF100/65-1.61.61100KWS65×2  DN100×1
SSPF150/65-1.61.61150KWS65×2  DN150×1
SSPF150/80-1.61.61150KWS80×2  DN150×1
SSPFT100/65-1.61.61100KWS65×2  DN100×1
SSPFT150/65-1.61.61150KWS65×2  DN150×1
SSPFT150/80-1.61.61150KWS80×2  DN150×1

Keywords

Anti collision pressure regulating ground fire hydrant SSFT100/65-1.6
+
  • Anti collision pressure regulating ground fire hydrant SSFT100/65-1.6

Anti collision pressure regulating ground fire hydrant SSFT100/65-1.6



Get A Quote

Note: Please leave your contact information and our professionals will contact you as soon as possible!

Submit